Sukladnost s GDPR-om i Politika kolačića. Pogledati u detalje
-15% UNIJECT VA stainless steel squirt, 1 pcs

UNIJECT VA stainless steel squirt, 1 pcs

UNIJECT VA Edelstahl Spritze

Proizvođači: Sanofi-Aventis Deutschland GmbH

Model: 01430286

Doziranje: Spritzen

Sadržaj: 1 St

Dostupnost: Nema na skladištu

$223.60

$189.85

iz Njemačkih ljekarni na Vašu adresu

0 recenzija / Napišite recenziju

-15% UNIJECT VA stainless steel squirt, 1 pcs

Upute za korištenje UNIJECT VA stainless steel squirt, 1 pcs

Instructions for use for: Uniject VA stainless steel syringes 1 pcs

Product features:

Uniject VA stainless steel compact model, cartridges and syringes with Selbstaspirationsmechanismus Aspiriervorrichtung for active aspiration

In Uniject VA stainless steel is Zylinderampullen syringes with Aspiriervorrichtung for use in dentistry. The cylinder ampoule syringes intended for injection in the context of infiltration and conduction anesthesia and their removal as well as for local instillation.

Uniject VA stainless steel with a folding mechanism for opening of the cylinder ampoule holder (The vial holder is fixedly connected to the syringe). Uniject VA vario stainless steel with slip for separate cartridge holder (The ampoule holder can be replaced).

The Uniject VA vario stainless steel can be practical as a spray rack with multiple cartridges holders use. An accessory pack with three additional ampoules holders is available.

For handling the Uniject VA stainless steel / stainless steel vario Uniject VA:
The cannula is attached directly to the syringe body. The equipment of the piston rod with three swivel hook allows a stable three-point anchoring in the hollow stopper of the cartridge and ensures a tilt-free guidance during injection and aspiration. By turning (clockwise) of the knurled screw the prongs are extended, retracted by turning (rotating counterclockwise). The rotating mechanism is equipped with a locking device. You will click into place once the tick are extended when turning right end position. Inadvertent release of the connection is excluded. When turning the thumbscrew for releasing the connection, the detent becomes noticeable as a slight initial resistance. For convenient handling, the UNIJECT VA is equipped stainless steel with a thumbning plate ring. It allows a controlled print application and facilitates working "with a fingertip feeling". Especially during aspiration, the thumbning plate ring makes engaging to retract the piston rod. Protect check mark from damage! When inserting or removing the cylinder ampoules, the anchoring checks must be retracted. You could otherwise be bent. Check out only for making the connection cylinder ampulle / piston rod and move back to releasate the connection! Pulling the check marks: left turning the knurled screw until the stop!

Insert the cylinder ampoubles:
At the UNIJECT VA stainless steel with folding mechanics: Piston rod completely withdraw. Finally, a spring resistor is to be overcome. Fold cylinder ampulle mount at right angles. The holder is open. Insert the cylinder ampoule. Fold back the holder in the longitudinal axis. Disconnect the piston rod against spring resistor completely. Release the spring resistor. The cylinder ampoule slides, centered by a guide ring, in the ampoule holder in the correct functional position.

At the UNIJECT VA VARIO stainless steel with plug-in device:
Return the piston rod completely. Finally, a spring resistor is to be overcome. If necessary, remove cylinder ampoult holder by side out of the splash of the syringe. Insert cylinder ampoult holder with pickled ampoule in the splash shoe of the splash. Disconnect the piston rod against spring resistor completely. Release the spring resistor. The cylinder ampoule slides, centered by a guide ring, in the ampoule holder in the correct functional position.

Connection piston rod - Cylinderampull stoppeckers:
Against the inserted cylinder ampoubles, the piston rod can be advanced a few millimeters: the front side of the piston rod with the check mark is firmly located in the recess of the hollow plug. The connection can be made by clearing the knurled screw. As soon as the check marks are swung out in the end position, the locking lock ensures the connection.

Aspiration:
Self-sapiration:
By a slight, short pressure on the syringe piston and instant release the thumb printing, the self-sample mechanism is triggered. Returning the elastic ampouline membrane, DIe is briefly pressed against a small cylindrical survey in the front end of the syringe, causes the necessary negative pressure in the ampoule, which ensures the self-spiracy.

Active aspiration:
By means of the 3 extendable and in the cylinder plugs to rotate to rotate the active aspiration, the active aspiration can continue to be carried out: the aspiration device is essentially based on the production of a fixed, pressurized and pulled connection between the hollow plug of the cylinder ampoules and the piston rod of the syringe. This attached connection allows easy aspiration and injecting.

General complications In the dental dental anesthesia are often due to unintentional intravenous or intraarterial injection. Effective failures can also occur during accidental intravascular injection, as the local anesthetic is quickly transported from the application location. The Liege Artis performed aspiration control largely protects against injecting into a blood vessel.

Cleaning / sterilization:
The instruments must be dismantled and cleaned after use. After cleaning and drying, mount the dry components and check the instrumentation for integrity. Follow this statement maintenance and care through. The purified and fully assembled instruments can now be sterilized.

Preparation:
In any case, the methods, facilities and devices validated at the user must be observed and to check for compatibility with the information given here. Reusable instruments and devices must be checked immediately before and after use as well as after cleaning for functionality and integrity. Prepare a contaminated instrument immediately after every use! Disassemble this (intended for disassembly) Instrument according to disassembly instructions in its items. Rinse the instrument thoroughly with clear, running water before machining cleaning and disinfection. Carefully remove coarse dirt with a soft cloth or a soft brush. Then clean manually or mechanically and absolutely avoid rinsing shadows. Be sure to observe the respective manufacturer's instructions.

Cleaning:
First remove adhering dirt with a soft plastic brush. Do not use abrasive detergents or metal brushes. Clean lumens and channels with a soft plastic brush. The diameters of lumens and brush must correspond to each other. Finally, rinse with distilled or ventilated, flowing water. Dry the instrument from the outside with an absorbent, soft and lint-free cloth. Blow lumen, channels and other inaccessible places with grease and dust-free compressed air dry. Clean and disinfect the instrumentation exclusively in a suitable cleaning and disinfection machine with a correspondingly reasonable procedure. Close items with lumens and channels directly on the special washing machine insert and non-ready-made instrumentation with a cleaning channel, if available, directly on the Luer-Lock approach on special washing machine use for cleaning the lumens. In the program selection, take into account the material (eg stainless instrument steel, chromed surface, aluminum) of the instrument to be cleaned! In any case, note the instructions of the device manufacturer! Finally rinse with Volltsalt water. Be sure to keep a sufficient drying phase. Take the instrument immediately after completing the program from the machine.

Clean Thermostable instruments with the Vario TD or BGA program. The following cleaning agents may be used: Deconex, Borer Chemistry (Cleaner), Mucapur-AF, Merz Consumer (Cleaner), Neodisher Z Dental, Dr. Refuses (cleaner, neutralizer).

Assembly and maintenance:
Allow the instrumentation to cool to room temperature. Oilize moving parts with a sterilizable, vapor permeable care oil. Mount the decomposable instrumentation.
After each cleaning and disinfection, check the full instrument:
  • Cleanliness
  • Function
  • Integrity (eg bent, broken, cracked, worn and broken parts).

Sort a damaged or defective instrumentation or replace defective parts. Use wear parts intended for disposable parts only once. Be sure to check the wearing parts for damage before each use and exchanges them if necessary. Pajunk recommends a careful use of care with the instruments as well as the unconditional observance of this instructions for use to achieve the long service life. The lifetime is significantly influenced by a long-term treatment and application of adequate maintenance and cleaning measures.

Sterilize with steam:
The steam sterilization must be after a validated steam sterilization method (eg sterilizer according to DIN EN 285 and validated according to DIN EN 17665-1). In an application of the fractionated vacuum procedure, perform sterilization with the 134 ° C / 3 bar program at a minimum stop time of 4 minutes. The dry season is 20 minutes. Allow devices / instruments to cool to room temperature before reuse. Store the instrumentation after steam sterilization exclusively in suitable, intended containers.

The following dental preparations of Sanofi in cylinder ampoules can be applied with UNIJECT VA stainless steel / uniject VA Vario stainless steel:
Ultracain D-S 1: 200.000 / Ultracain D-S Forte 1: 100.000
Ultracain D without adrenaline
Dontisolon D cylinder ampoules
Oraverse 400 micrograms / 1.7 ml injection solution

Packs and accessories:
Pack of 1 UNIJECT VA stainless steel
Pack of 1 UNIJECT VA VARIO stainless steel (incl.1 Cylinder ampoul holder)
Accessory packing UNIJECT VA VARIO stainless steel with 3 ampoule holders

Manufacturer:
Pajunk GmbH Medical Technology Karl-Hall-Str. 1, 78187 Goe

Status of Information: March 2014

Source: www. sanofi. de
Status: 01/2015

Recenzije lijekova

Nema recenzija za taj artikl.

Napišite recenziju

* Ocjena Loše Dobro

Povezani artikli

-15% Frankincense Compl7 Leinersan, 120 pcs

Frankincense Compl7 Leinersan, 120 pcs

WEIHRAUCH COMPLEX 7 Leinersan Kapseln

$38.20 $45.01

Popularno u Sprej & kanule

STERICAN Cannulas luer-lok 0,40x20 mm Veličina 20 siva, 100 STS

STERICAN Cannulas luer-lok 0,40x20 mm Veličina 20 siva, 100 STS

STERICAN Kanülen Luer-Lok 0,40x20 mm Gr.20 grau

$7.53

STERICAN Cannulas luer-lok 0,90x40 mm gr.1 žuti, 100 ST

STERICAN Cannulas luer-lok 0,90x40 mm gr.1 žuti, 100 ST

STERICAN Kanülen Luer-Lok 0,90x40 mm Gr.1 gelb

$6.86

BUTTERFLY Kanila 21 g zelena, 1 ST

BUTTERFLY Kanila 21 g zelena, 1 ST

BUTTERFLY Kanüle 21 G grün

$2.17

STERICAN INS.M.KAN.26 GX1/2 0,45X12 mm, 100 ST

STERICAN INS.M.KAN.26 GX1/2 0,45X12 mm, 100 ST

STERICAN Ins.Einm.Kan.26 Gx1/2 0,45x12 mm

$9.97

STERICAN Cannulas luer-lok 0,45x25 mm gr.18 smeđa, 100 ST

STERICAN Cannulas luer-lok 0,45x25 mm gr.18 smeđa, 100 ST

STERICAN Kanülen Luer-Lok 0,45x25 mm Gr.18 braun

$7.53

INJEKT Solo šprica 10 ml Luer Excentric PVC-fr., 100x10 ml

INJEKT Solo šprica 10 ml Luer Excentric PVC-fr., 100x10 ml

INJEKT Solo Spritze 10 ml Luer exzentrisch PVC-fr.

$15.32

INJEKT Solo šprica 20 ml luera ekscentričnog PVC-fr., 100x20 ml

INJEKT Solo šprica 20 ml luera ekscentričnog PVC-fr., 100x20 ml

INJEKT Solo Spritze 20 ml Luer exzentrisch PVC-fr.

$22.65

BD DISCARDIT II Proljeće 5 ml, 100x5 ml

BD DISCARDIT II Proljeće 5 ml, 100x5 ml

BD DISCARDIT II Spritze 5 ml

$10.04